There is no height requirement listed. Like internal maintenance, hydrostatic testing is done at different intervals based on the type of extinguisher you have. Please log in as a SHRM member before saving bookmarks. 0 How to Pass an OSHA Fire Extinguisher Inspection with its use or operation. The employer shall assure that stored pressure dry chemical extinguishers that require a 12-year hydrostatic test are emptied and subjected to applicable maintenance procedures every 6 years. The employer shall assure that hydrostatic tests are performed on extinguisher hose assemblies which are equipped with a shut-off nozzle at the discharge end of the hose. Other observations could be documented as well such as the exact location and its current condition. The employer shall remove from service all soldered or riveted shell self-generating soda acid or self-generating foam or gas cartridge water type portable fire extinguishers which are operated by inverting the extinguisher to rupture the cartridge or to initiate an uncontrollable pressure generating chemical reaction to expel the agent. Please confirm that you want to proceed with deleting bookmark. The fire extinguisher must be located within 20 feet of where the open flame is used. Do a visual check and assess the visibility and accessibility of the fire extinguisher: Pick up the fire extinguisher and check for physical defects or anything that your checklists instructs to look for such as: The needle of the pressure gauge should be within the green zone. The employer shall assure that portable extinguishers are hydrostatically tested at the intervals listed in Table L-1 of this section, except under any of the following conditions: When the unit has been repaired by soldering, welding, brazing, or use of patching compounds; When the cylinder or shell threads are damaged; When there is corrosion that has caused pitting, including corrosion under removable name plate assemblies; When the extinguisher has been burned in a fire; or. FIRE EXTINGUISHER INSPECTION. The mechanical parts the nozzle, body, handle, pin and seal, lever, and dip tube. They may also want to see or know about your fire prevention plan, which is itself part of your evacuation plan. An OSHA Inspector who's inspecting your fire extinguisher may look for compliance with any of the following general requirements for fire extinguishers: Make sure your portable fire extinguishers are in compliance with all of the general requirements listed above. If you have interior standpipes and valves, are they inspected regularly? Indicate the overall condition of the extinguisher if pass or fail. The employer shall assure that portable fire extinguishers are subjected to an annual maintenance check. At times incidents that occur can point out the need to focus on a particular industry or type of operation. National Fire Protection Association (NFPA) 2022, National Fire Codes Subscription Service, The value of Standards Development Organizations, Alternative Fuel Vehicles Safety Training, Reducing Wildfire Risk to People and Property, State-approved NEC and NFPA 70E electrical online training, Certification for Electrical Safety in the Workplace, Safety in living and entertainment spaces, Submit a Public Input for the Next Edition. (+5 Key Benefits), What is a Backflow Preventer? 0000000016 00000 n Portable fire extinguisher inspection is extremely important for the protection of businesses and homes especially since OSHA and Fire Codes require specific procedures when it comes to fire extinguishers in the workplace. PDF Commercial Passenger Vehicle Inspection Manual In addition, this provision requires employers to retain the inspection record for one year after the last entry or for the life of the shell, whichever is less, and to . Closed storage compartments in which . In addition to or as part of the internal maintenance examination, periodically the fire extinguisher cylinders must be hydrostatically tested to ensure their integrity and ability to safety contain the pressure used to expel the agent. The employer shall be responsible for the inspection, maintenance and testing of all portable fire extinguishers in the workplace. New Marine Fire Extinguisher Law for Boats | Boating Mag Step 1 - Walk up to the extinguisher and ensure it has a valid maintenance tag. Fire extinguishers need to have an external maintenance examination conducted on a yearly basis, at the time of hydrostatic test, or when specifically indicated by an inspection discrepancy. What happens during an OSHA inspection, and what triggers them? How often do fire extinguishers need to be inspected? Are fire doors and shutters in good operating condition? vacuum does not meet the requirements listed above Emergency Equipment: Fire Extinguisher CFR 393.95(a), Reject if: a. This fire extinguisher inspection checklist is used to sufficiently do a fire extinguisher inspection in less than 3 minutes. Is the extinguisher in a designated and unobstructed location? Again, though, many employers find it easier to manage this aspect of their health and safety programs by using a system to document these sessions. The employer may use uniformly spaced standpipe systems or hose stations connected to a sprinkler system installed for emergency use by employees instead of Class A portable fire extinguishers, provided that such systems meet the respective requirements of 1910.158 or 1910.159, that they provide total coverage of the area to be protected, and that employees are trained at least annually in their use.